Pilot light is on, no flahing lights on the circuit board on the unit.Ive replace the batteries on the wall controller just in case.
IT fires up, I can here the fan going but no heat Please help. Thanks Plum, is that the part where the pilot light knob is Can you attach an image please And how much does one of those cost and more importantly.what would be a reasonble price to pay for someone to come and replace this Sorry for the many questions but us Noobs usually get ripped off by these big companies that come out and start charging before they even look at it. Having said that, it could also be a burnt out transformer, as youve suggested it is an old unit, is the external case brown in colour sometimes its not worth spending money on these units because of the age and condition of the heat exchanger. The cover on the outside unit has Electronic ignition reigniter displayed. The LEDs inside light up and make igniting noises, but there are also sounds like electrical short noises. They quite often fail or you may have an issue with something else. I know you have said that the gas is on, but is the pilot actually alight. Maybe something is exposed that should not be As far as what blew, its not likely to be the motor as it would not have energized the motor as yet, it only does that when it is turned on. ![]() Buffalo 120 EMS. View and Download Brivis BX3 service manual online. Brivis Buffalo Service Download Brivis BuffaloJan 17, 2018 - View online or download Brivis Buffalo 20 XA Installer Manual. Feb 2014 Service Manual 19 Heater EMS (2) Series Aprroved Issue 1. I initially suspected that I had a faulty appliance so I did an insulation breakdown test on all the appliances. All of them checked out okay except for the central heating unit that showed a little bit of leakage. I left the central heating unit unplugged, but the tripping remained. The tripping fault was eventually found to be a rodent chewed cable. In the process, the power outlet to the central heater (fitted by the heating installer) was wired with the active and neutral transposed. The problem: The central heating unit has been left unplugged for several months now, but I thought I should plug it in in preparation for when it is next needed. At first, nothing happened when I plugged it in (and I didnt expect anything to happen). However, when I checked the controller inside, the screen was still blank. I figured that maybe I plugged it in but had forgot to switch it on I went under the house again to check. It was on, so I thought Id try the other outlet (its a double outlet) just in case. When I plugged it in to the other outlet and switched on - something unexpected happened. It went BANG And there was a flash near the right-hand side vent (the one nearest the star sticker). I turned everything off and removed the cover to look for any obvious problems. The nearest I can tell, is that the flash may have been near the blower motor. The motor rotates very freely so Im not convinced it is the motor. Also, I didnt realise it at the time, but the circuit breaker tripped too. Does anyone have any ideas or pointers as to what might be wrong Ill probably have to wait until the weekend before I have time to look further. From memory when you restore mains power nothing happens until you hit power on the Networker panel. One thing that does look a bit odd is that to my mind your unit is on its side. At least for a HE30, its all top accessible, not side-accessible. If thats the case maybe having turned on power while its on its side is an issue As far as what blew, its not likely to be the motor as it would not have energized the motor as yet, it only does that when it is turned on. From memory there is a fuse for the internal controller, maybe see if you can find that.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |